Non-shrink grout is used wherever a cementitious material must fill a confined space, maintain full contact with surrounding surfaces, and transfer loads without shrinking away from the substrate.
Instead of purchasing a prepackaged grout, contractors and concrete producers can use a non-shrink grout admixture to modify a properly proportioned cement-and-sand mixture. The admixture helps compensate for the volume loss that normally occurs as cementitious materials hydrate and cure.
When correctly designed, mixed, placed, and cured, the resulting grout can provide strong bearing support, reliable bond, and long-term dimensional stability.
Here are five of the most common applications for non-shrink grout admixtures.
1. Grouting Machinery and Equipment Base Plates
One of the most widely recognized uses for non-shrink grout is filling the space beneath machinery and equipment base plates.
Even when a concrete foundation appears level, small surface irregularities can prevent a steel base plate from bearing evenly against the concrete. Without complete contact, equipment loads may become concentrated at isolated points.
Non-shrink grout flows or is packed beneath the plate to fill these irregularities and create a continuous bearing surface.
Common examples include:
- Pumps
- Compressors
- Generators
- Industrial presses
- Conveyors
- Manufacturing equipment
Maintaining grout volume is especially important in these applications. If the grout shrinks away from the underside of the plate, it can create voids that reduce bearing area and allow movement or vibration.
A properly proportioned non-shrink grout helps distribute loads more evenly between the equipment and the supporting foundation.
2. Anchoring Bolts, Dowels, and Reinforcing Steel
Non-shrink grout is also commonly used to secure anchor bolts, dowels, reinforcing bars, and other embedded components.
These elements may be placed in formed blockouts or drilled holes and then surrounded with grout. The grout must completely fill the available space and remain in close contact with both the embedded steel and the surrounding concrete.
Typical applications include:
- Structural anchor bolts
- Equipment hold-down bolts
- Column base anchors
- Reinforcing bar dowels
- Guardrail posts
- Sign supports
- Precast connections
Ordinary cement grout may shrink as it cures, potentially reducing contact around the embedded element. A non-shrink grout admixture helps compensate for this volume change, improving the grout’s ability to maintain a tight, uniform fit.
The grout must still be designed with appropriate flow, strength, aggregate size, and installation consistency for the dimensions of the opening.
3. Filling Voids and Repairing Honeycombed Concrete
Voids and honeycombed areas can occur when concrete does not fully consolidate around reinforcement, formwork, or embedded components. These defects may reduce durability, expose reinforcing steel, or interrupt the intended load path through the structure.
A non-shrink grout can be used to fill properly prepared cavities and restore solid contact within the repair area.
Common repair locations include:
- Honeycombed walls
- Columns
- Foundations
- Beam pockets
- Precast elements
- Areas around congested reinforcing steel
The repair area must first be evaluated to determine the cause and extent of the defect. Loose or unsound concrete should be removed, and the substrate should be cleaned and prepared before grouting.
The grout consistency should also match the repair geometry. Flowable grout may be suitable for enclosed voids, while a stiffer, dry-pack consistency may be more appropriate for overhead or vertical repairs.
Because the grout is restrained by the surrounding concrete, controlling shrinkage is critical. Excessive volume loss can lead to separation, poor bond, or incomplete support within the repaired area.
4. Supporting Structural Steel and Precast Components
Non-shrink grout is frequently placed beneath structural elements that require continuous, uniform support.
Examples include:
- Steel column base plates
- Bridge bearing plates
- Precast wall panels
- Precast columns
- Structural beams
- Crane rails
- Bearing pads
These components often transfer substantial loads into foundations, piers, slabs, or other supporting members. The grout fills the gap between the structural element and the bearing surface, compensating for construction tolerances and surface irregularities.
The objective is not simply to fill empty space. The grout must create a stable load-transfer layer.
If the grout settles, bleeds excessively, or shrinks after placement, the supported component may lose full bearing contact. This can produce concentrated stresses or movement under service loads.
Non-shrink grout admixtures help produce a more dimensionally stable grout layer, but installation practices remain essential. The grout must be placed continuously, consolidated as required, protected from moisture loss, and cured according to the project specifications.
5. Grouting Around Pipes, Sleeves, and Penetrations
Non-shrink grout is commonly used to fill annular spaces around pipes, sleeves, conduits, and other penetrations through concrete.
These openings are often intentionally oversized to simplify installation and alignment. After the pipe or sleeve is positioned, the remaining space must be filled with a durable cementitious material.
Typical applications include:
- Pipe penetrations through walls
- Utility sleeves
- Drain lines
- Conduit penetrations
- Mechanical equipment connections
- Pipe supports
- Openings in foundations and slabs
The grout helps secure the penetration, fill irregular spaces, and provide a solid transition between the embedded item and the surrounding concrete.
Depending on the project, additional waterproofing or flexible sealing materials may also be required. Non-shrink grout provides rigid support and void filling, but it should not automatically be treated as a replacement for a specifically designed waterproofing or movement joint system.
Why Use a Non-Shrink Grout Admixture?
A non-shrink grout admixture allows producers and contractors to create grout using locally available cement and properly graded aggregate rather than relying exclusively on prepackaged materials.
This can be especially useful for:
- Large-volume grout placements
- Remote projects
- Custom batch sizes
- Applications requiring adjustable consistency
- Projects using on-site or ready-mix production
The admixture is designed to compensate for normal cementitious shrinkage and help maintain contact within confined spaces. Depending on the formulation, it may also improve flow, reduce water demand, control bleeding, or generate controlled expansion during the grout’s early curing period.
However, the admixture cannot compensate for a poorly designed mix or improper installation. Successful non-shrink grout requires control of several variables, including:
- Water content
- Cement-to-aggregate ratio
- Aggregate grading
- Mixing time
- Placement consistency
- Substrate preparation
- Formwork
- Temperature
- Curing
Adding excess water to improve flow can increase bleeding, segregation, porosity, and drying shrinkage. Flow should be developed through the proper mixture design and admixture dosage—not uncontrolled water addition.
Final Considerations
Fritz-Pak’s NS-7 provides controlled expansion for any of your non-shrink grout projects. It comes packaged in our signature, water-soluble bags for easy dosing and mixing on site. Visit the online store today to learn more or to order your case today.