Concrete rejection at the job site often comes down to one issue: air content outside project specifications. For ready-mix producers, an air reading that is too high can delay placement, increase costs, or result in a rejected load.
When excess entrained or entrapped air must be removed to increase concrete density, an air detrainer can be an effective corrective admixture. However, air detrainers only work as intended when they are applied correctly. Below are the most common mistakes producers make when using an air detrainer, such as Fritz-Pak Air Minus, and how to avoid them.

1. Using Too Little Air Detrainer

Many commonly used admixtures—superplasticizers, water reducers, and air-entraining admixtures—increase concrete air content. When these products are present, a standard air detrainer dosage may not be sufficient to counteract their effects.

If air content remains high after treatment, the issue may not be product performance—it may be underdosing. In some cases, a significantly higher dose of air detrainer is required to overcome the air-adding influence of other admixtures in the mix.

Key takeaway: Persistent high air readings often indicate the need for dosage adjustment, not abandonment of the detrainer.

2. Mixing at High Speed for Too Long

Air detrainers behave differently from most concrete admixtures. Extended high-speed mixing can actually increase air content by creating foam within the mix.

Best practice mixing procedure:

  • Mix at high speed for 2–3 minutes after adding the air detrainer
  • Then reduce to slow or transit speed for an additional 3 minutes

Key takeaway: Overmixing at high speed can negate the benefits of an air detrainer.

3. Waiting Too Long to Add the Air Detrainer

Air detrainers require time to react and stabilize within the concrete. Testing immediately after mixing often produces misleadingly high air readings.

For accurate results:

  • Allow the load to rest for 5–10 minutes after mixing
  • Then perform air testing once the entrapped air has had time to dissipate.

This resting period improves test reliability and reduces unnecessary corrective actions.

Key takeaway: Premature testing can make an effective air detrainer appear ineffective.

When an Air Detrainer Can’t Save the Load

Even when best practices are followed, not every load can be corrected. Extreme air levels, incompatible admixture combinations, or excessive mixing history may limit the effectiveness of an air detrainer.
Bottom line: Air detrainers are powerful corrective tools—but only when dosage, mixing, and timing are carefully controlled.

This guidance is based on industry best practices and field experience. Always follow project specifications and product technical data sheets.